Fluke Calibration 8588A Reference Multimeter

Tuotekoodi: 4983182

Kysy lisää meiltä!

Supports minimum of 100,000 readings per second at 4.5 digits across GPIB, USB or Ethernet.

Digitizing multimeter designed specifically for calibration laboratories, metrologists, automated test equipment (ATE), and semiconductor characterization.

More than 12 measurement functions; digitize voltage, digitize current, and external shunts for DC and AC current, consolidating into a single instrument.


Mikäli tuotteella ei ole näkyvissä hintaa, pyydä tarjous.

Bench multimeters

Fluke Calibration digital bench multimeters have the precision and versatility to handle the most demanding measurements, on the bench or in a system. These benchtop DMMs are easy to use and offer excellent value that makes them an ideal solution for many applications. Standards laboratory DMMs include: Reference multimeters, precision digital multimeters, and bench multimeters.

Product overview: 8588A High Precision Bench Multimeter

Precision, Stability, and Throughput

The Fluke Calibration 8588A Reference Multimeter is engineered for ultra-stable, low-noise performance, designed for metrologists, automated test equipment, semiconductor characterization within semiconductor manufacturing, and high-accuracy calibration labs. With best-in-class linearity and long-term stability, it delivers 3.5 ppm one-year DC voltage relative accuracy and 8.5-digit resolution in one second, without daily internal self-calibration or autozeroing. Gain higher throughput and measurement confidence in the most demanding production environments.

A modern, multilingual UI and visualization tools streamline setup, training, and analysis. Perform real-time and post-capture evaluation—trends, histograms, FFT, and statistics—without a PC. Visual Connection Management™ guides correct connections, while front/rear input switching supports ratio, difference, and deviation workflows.

  • Graphical display: trend plots, histograms, FFT, and statistical views for quick insight.
  • Interfaces: Ethernet, GPIB, USBTMC for system control; USB host (front/rear) for .csv export and firmware updates.
  • Compatibility: Full Fluke 8508A emulation and Keysight 3458A SCPI command compatibility to accelerate upgrades.
  • Front/rear input scanning for ratio/difference/deviation in DCV and resistance.
  • Capacitance and RF power readout support (Rohde & Schwarz NRP Series) to extend multi-product calibration capability.

DC Accuracy & Long-Term Stability

Custom-crafted, ultra-stable voltage references and attenuators—designed by Fluke Calibration—preserve accuracy over time and temperature. Ultra-stable amplifier offsets eliminate the need for autozeroing, reducing cycle time in automated sequences. This architecture maintains superior accuracy and repeatability across a wide range of DC voltage and resistance measurements, even under rigorous semiconductor, GPU/Power-Cell Characterization and ATE workloads.

 

Key DC Performance

  • DC voltage relative accuracy: 2.7 µV/V (95%), 3.5 µV/V (99%), 1-year—without internal self-calibration or auto-adjustments.
  • DC stability (24-hour): 0.5 µV/V (95%), 0.65 µV/V (99%).
  • Resistance accuracy (1-year): 7 µΩ/Ω (95%), 9 µΩ/Ω (99%).
  • 2.02× full-scale stretch lowers noise floor and extends dynamic range for higher accuracy.
  • Aperture control: 200 ns to 100 s for precise data windowing in semiconductor and ATE applications.

 

 

World-Class AC RMS Performance for Low-Level Signals

With a 5 MS/s ADC and a highly stable analog path, the 8588A achieves AC measurements that are up to 10× faster, 2× lower noise, and more sensitive for low-level signals than other instruments in its class. Digital RMS calculations retain full resolution across a wide dynamic range, while rapid digital filters avoid dielectric absorption effects common to analog filters—shortening settling to within 6 cycles of the filter frequency and <1 ppm of final value.

  • AC voltage accuracy: 60 µV/V (95%), 77 µV/V (99%), 1-year.
  • AC current accuracy: 250 µA/A (95%), 323 µA/A (99%), 1-year.
  • Settling time: ~15 ms at 1 kHz AC filter—up to 10× faster for AC voltage measurement.
  • Dynamic range: 2.02× Vpp, 1.2× Vrms full scale.
  • Peak AC current up to 30 A extends high-current test coverage in ATE.

Optional 8588A Null Detector for Standards and System Balancing

The 8588A/Null Meter option replaces analog null detectors for exacting comparisons between standards or between primary and secondary references. It enables rapid, automated, and precise zero-difference detection to balance systems and minimize uncertainty.

 
  • Bias current: specified <20 pA (typical <5 pA).
  • Balanced resistor network resolution: typically 0.2–0.5 ppm.
  • Selectable ranges: ±100 nV to ±100 mV optimized for null applications.
  • Responsiveness: <1 s at 8.5-digit resolution for fast tuning and automation.
  • Integrated 5 Hz low-noise filter for superior performance vs. analog null meters.
  • Flexible speed/settling settings for automated sequences.

System Integration & Migration (3458A / 8508A)

The 8588A/8558A instruments provide full emulation of the Fluke 8508A and limited emulation of SCPI command compatibility with the Keysight 3458A, enabling rapid migration in legacy ATE and semiconductor test systems. This reduces programming rework, shortens validation time, and lowers risk when replacing aging long-scale DMMs.

See how one calibration lab transitioned from the 3458A to the 8588A to improve speed, accuracy, and overall workflow efficiency. Read the 8588A case study.

The Clear Choice for ATE and Semiconductor Applications

  • High throughput: 8.5-digit reading in 1 s—twice as fast as competitive instruments for shorter test cycles.
  • Drop-in system migration: SCPI command compatibility with Keysight 3458A and full Fluke 8508A emulation to minimize code changes.
  • Exceptional long-term stability: Ultra-stable voltage references and attenuators eliminate drift-related daily adjustments.
  • Low noise floor: 2.02× full-scale stretch and wide aperture control maximize precision at low signal levels.
  • Flexible data capture: 200 ns to 100 s aperture settings support diverse semiconductor and ATE measurement windows.
  • Robust I/O: Ethernet, GPIB, USBTMC, plus front/rear USB host for data export and updates.
  •  

Technical Specifications (At-a-Glance)

  • DCV one-year relative accuracy: 3.5 ppm; 24-hour stability down to 0.5 µV/V (95%).
  • Resistance (1-year): 7–9 µΩ/Ω.
  • ACV (1-year): 60–77 µV/V; AC current (1-year): 250–323 µA/A.
  • Measurement speed: 8.5-digit in 1 second; AC settling ~15 ms @ 1 kHz filter.
  • Aperture: 200 ns to 100 s; Dynamic range stretch: 2.02× full scale.
  • Peak AC current: up to 30 A; Null ranges: ±100 nV to ±100 mV.
  •  

The MET/CAL™ Calibration Management Software advantage

The 8588A and 8558A work with Fluke Calibration MET/CAL™ Calibration Software with native MET/CAL support or using 8508A emulation mode to increase throughput up to four times that of traditional manual and multi-product methods while ensuring calibrations are performed consistently every time. This powerful software documents calibration procedures, processes and results for ease in complying with ISO/IEC 17025 and similar quality standards.

Support and services when you need them

Fluke Calibration offers testing, repair and calibration services to meet your needs quickly and at a fair cost while maintaining the high level of quality that you expect. Our electrical calibration laboratories are accredited for conformance to ISO Guide 17025 and we maintain global calibration and repair facilities.

You can enhance warranty protection with a Priority Gold Instrument CarePlan service package.

A Priority Gold Instrument CarePlan includes an expedited annual calibration to reduce downtime by a week and extended warranty to help ensure the best long-term performance from your instruments. Choose from one-year, three-year or five-year CarePlans. (Note: Priority shipping times vary by country. Contact your local Fluke Calibration sales representative for details.)

FAQs

Is the 8588A a drop-in replacement for Keysight 3458A in ATE systems?

The 8588A/8558A support SCPI command compatibility with the 3458A and full emulation of the Fluke 8508A, significantly reducing code changes and validation time in legacy ATE environments.

How does the 8588A improve semiconductor test throughput?

It delivers an 8.5-digit reading in one second and features fast digital filters with ~15 ms settling at 1 kHz, cutting wait times and accelerating test sequences.

What benefits does the Null Detector option provide?

It enables ultra-precise zero-difference measurements between standards with selectable ±100 nV to ±100 mV ranges and <1 s responsiveness, ideal for automated balancing and comparison workflows.

Can I control the 8588A via common ATE interfaces?

Yes. It supports Ethernet, GPIB, and USBTMC for system integration, plus front/rear USB host ports for data export and firmware updates.


  • Tuotekoodi: 4983182
Key feature and specification comparison 8588A 8558A
DC voltage 100 mV – 1000 V 100 mV – 1000 V
AC voltage 10 mV – 1000 V, 1 Hz – 10 MHz 10 mV – 1000 V, 1 Hz – 10 MHz
Resistance, LoI, HV 1 Ω - 10 GΩ 1 Ω - 10 GΩ
DC current 10 uA – 30 A 10 uA – 2 A
AC current 10 uA – 30 A, 1 Hz to 100 kHz 10 uA – 2A, 1 Hz to 100 kHz
Digitize V 100 mV - 1000 V, 5 MSamples/s, up to 20 MHz BW 100 mV - 1000 V, 5 MSamples/s, up to 20 MHz BW
Digitize I 10 uA - 30 A, 5 MSamples/s, up to 4 MHz BW 10 uA - 2 A, 5 MSamples/s,
up to 4 MHz BW
Frequency (V, I, BNC) 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz 1 Hz to 10 MHz, 1 Hz to 100 kHz, 10 Hz to 100 MHz
Temperature PRT / Thermocouple (ext CJC) PRT / Thermocouple (ext CJC)
Capacitance 1 nF – 100 mF No
RF power R&S NRP Series No
Ext. dc current and ac current A40B current shunt and other shunts No
Graphical display Yes Yes
Visual Connection Management ® Yes Yes
Programmable front/rear input switching Yes Yes
Ratio difference, deviation -  ohms, voltage, current Yes Yes
External 10 MHz ref clock, 50 Ω/Hi-Z Yes Yes
A40B and other shunt asset management Yes No
GPIB 488.2, Ethernet, USB TMC Yes Yes
SCPI command compatibility Yes Yes
3458A emulation, 8508A emulation Yes Yes
Volatile memory 15 million 15 million
Level and other trigger Yes Yes
FFT onboard Yes No
Reading rates: 5 MS/s into memory, bus: 100 kS/s at 4.5 digits, 1 rdg/s at 8.5 digits Yes Yes

 

Function     8588A uX/X of reading + uX/X of range  8558A uX/X of reading + uX/X of range 
      95% 99% 95% 99%
DC voltage 10 V relative 2.7 + 0.05 3.5 + 0.06 4.0 + 0.06 5.2 + 0.08
absolute 2.8 + 0.05 3.6 + 0.06 4.1 + 0.06 5.3 + 0.08
AC voltage 10 V, 1 kHz relative 60 + 5 77 + 6.5 80 + 10 103 + 13
absolute 64 + 5 83 + 6.5 90 + 10 116 + 13
Resistance 10 kΩ relative 7 + 0.5 9 + 0.6 10 + 0.6 13 + 0.7
absolute 7.2 + 0.5 9.2 + 0.6 10.3 + 0.6 13.3 + 0.7
DC current 1 mA relative 6.5 + 4 8.4 + 5 9 + 5 12 + 6
absolute 7.6 + 4 10 + 5 9.8 + 5 13 + 6
AC current 1 mA, 1 kHz relative 250 + 50 323 + 65 300 + 100 387 + 129
absolute 260 + 50 335 + 65 310 + 100 400 + 129
Frequency BNC,1 kHz relative 0.5 uHz/Hz 0.5 uHz/Hz 0.5 uHz/Hz 0.5 uHz/Hz
Temperature PRT 100 Ω relative ± 5 mK ± 5 mK ± 5 mK ± 5 mK
Capacitance 1 uF relative 400 + 100 516 + 129 N/A N/A
absolute 406 + 100 523 + 129 N/A N/A


95% 1 year relative specification. Fluke Calibration guarantees to 99% confidence interval k=2.58. For 99%, multiply by (2.58/2).

Looking for lower specs? See our other benchtop multimeters:

Bench Multimeter Selection Guide

Model Resolution Accuracy Application
8588A 8.5 2.7 µV/V 95% confidence level, 1 year relative accuracy Metrology
8558A 8.5 4.0 µV/V 95% confidence level, 1 year relative accuracy High-Speed Automation
8845A/8846A 6.5 Basic V dc accuracy of up to 0.0024 % Bench
8808A 5.5 Basic V dc accuracy of 0.015 % Bench