Fluke Calibration 5730A High-Performance-Calibrator

Tuotekoodi: 4334885

Kysy meiltä lisää!

5720 ja 5700 -sarjan emulointi.

8,5 digitin yleismittareiden kalibrointi, kuten 3485A ja 8558A

Calibrate up to long-scale 8.5 digit digital multimeters and RF voltmeters with wideband option.
Improved AC voltage, AC current, and resistance specifications for increased test uncertainty ratios (TURs).
6.5-inch VGA touchscreen, a full-color interface, and Visual Connection Management™ output terminals
Full Met/CAL® compatibility with 5700A and 5720A procedures


Mikäli tuotteella ei ole näkyvissä hintaa, pyydä tarjous.

Product overview: 5730A High Performance Multifunction Calibrator

The calibrator for those who demand the best

The 5730A is designed for calibration professionals who require the most accurate dc/lf signals available in a multifunction calibrator, as well as those who simply want the best calibrator available. Metrologists in national laboratories, the military, third party calibration laboratories, and corporate users with high-end workload will value the performance and reliability of the 5730A. All 5730A calibrators are traceable to international standards and are produced in the factory with ISO/IEC 17025 accredited calibrations. Specifications are stated to the standard Fluke Calibration 99 % confidence level (as well as 95 % confidence level) to support easy measurement comparisons according to international quality standards. Specifications are absolute and include the uncertainty of the calibration standards used. No additional analysis is required.


  • Tuotekoodi: 4334885
Technical Specifications
Voltage DC Range 0 to ±1100 V
Best 1 Year, 95% Specification 3.5 ppm + 2.5 µV
Voltage AC Range 22 µV to 1100V
10 Hz to 1 MHz
Best 1 Year, 95% Specification:  42 ppm + 8 µV
Resistance Range 0 to 100 MΩ, 18 values in x1 and x1.9
Best 1 Year, 95% Specification 6.5 ppm
Current DC Range 0 to ±2.2A (0 to ±11A with 5725A; 0 to ±100 A with 52120A)
Best 1 Year, 95% Specification 35 ppm + 7 nA
Current AC Range 9 µA to 2.2A, 10 Hz to 10 kHz
(9 µA to ±11A with 5725A; 9 µA to ± 120 A with 52120A)
Best 1 Year, 95% Specification 103 ppm + 8 nA
Wideband ac Voltage option Range 300 µV to 3.5V
10 Hz to 50 MHz
Best 1 Year, 99% Specification 0.4% + 500 µV
General Specifications
Warm up time Twice the time since last warmed up, to a maximum of 30 minutes
Settling time Less than 5 seconds for all functions and ranges except as noted
Standard interfaces IEEE-488 (GPIB), RS-232, USB 2.0 Device, Ethernet, 5725A, 52120A, phase lock in (BNC), phase reference out (BNC)
Temperature performance Operating 0 °C to 50 °C
Calibration:15 °C to 35 °C 15 °C to 35 °C
Storage -40 °C to 75 °C
Operating altitude 2000 m maximum
Relative humidity Operating < 80% to 30 °C, < 70% to 40 °C, < 40% to 50 °C
Storage < 95%, non-condensing.
Safety IEC 61010-1: 300 V CAT II, Pollution Degree 2
Analog low isolation 20 V
Electromagnetic environment IEC 61326-1: Controlled
Line power 47 Hz to 63 Hz; ±10% 100 V, 110 V, 115 V, 120 V, 200 V, 220 V, 230 V, 240 V
Power consumption 300 VA
Dimensions Height 17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet
Width 43.2 cm (17 in), standard rack width
Depth 64.8 cm (25.5 in), overall; 59.4 cm (23.4 in), rack depth
Weight 27 kg: (62 lbs.)
Absolute uncertainty definition 5730A uncertainty specifications include stability, temperature coefficient, linearity, load regulation, and the traceability of the external standards used for calibration. You do not need to add anything to determine the total uncertainty of your calibrator for the temperature range indicated
Specification confidence interval 99% and 95%
Technical Specifications
Voltage DC Range 0 to ±1100 V
Best 1 Year, 95% Specification 3.5 ppm + 2.5 µV
Voltage AC Range 22 µV to 1100V
10 Hz to 1 MHz
Best 1 Year, 95% Specification:  42 ppm + 8 µV
Resistance Range 0 to 100 MΩ, 18 values in x1 and x1.9
Best 1 Year, 95% Specification 6.5 ppm
Current DC Range 0 to ±2.2A (0 to ±11A with 5725A; 0 to ±100 A with 52120A)
Best 1 Year, 95% Specification 35 ppm + 7 nA
Current AC Range 9 µA to 2.2A, 10 Hz to 10 kHz
(9 µA to ±11A with 5725A; 9 µA to ± 120 A with 52120A)
Best 1 Year, 95% Specification 103 ppm + 8 nA
Wideband ac Voltage option Range 300 µV to 3.5V
10 Hz to 50 MHz
Best 1 Year, 99% Specification 0.4% + 500 µV
General Specifications
Warm up time Twice the time since last warmed up, to a maximum of 30 minutes
Settling time Less than 5 seconds for all functions and ranges except as noted
Standard interfaces IEEE-488 (GPIB), RS-232, USB 2.0 Device, Ethernet, 5725A, 52120A, phase lock in (BNC), phase reference out (BNC)
Temperature performance Operating 0 °C to 50 °C
Calibration:15 °C to 35 °C 15 °C to 35 °C
Storage -40 °C to 75 °C
Operating altitude 2000 m maximum
Relative humidity Operating < 80% to 30 °C, < 70% to 40 °C, < 40% to 50 °C
Storage < 95%, non-condensing.
Safety IEC 61010-1: 300 V CAT II, Pollution Degree 2
Analog low isolation 20 V
Electromagnetic environment IEC 61326-1: Controlled
Line power 47 Hz to 63 Hz; ±10% 100 V, 110 V, 115 V, 120 V, 200 V, 220 V, 230 V, 240 V
Power consumption 300 VA
Dimensions Height 17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet
Width 43.2 cm (17 in), standard rack width
Depth 64.8 cm (25.5 in), overall; 59.4 cm (23.4 in), rack depth
Weight 27 kg: (62 lbs.)
Absolute uncertainty definition 5730A uncertainty specifications include stability, temperature coefficient, linearity, load regulation, and the traceability of the external standards used for calibration. You do not need to add anything to determine the total uncertainty of your calibrator for the temperature range indicated
Specification confidence interval 99% and 95%